After installing ESXi 5. I opted to try using the ESXi console. I downloaded the latest MegaCLI version 8. It contained a VIB.

megacli firmware update

While annoying I figured there must be an option to not verify the signature of the VIB. The esxcli help showed an option to do this. I downloaded the latest firmware to my laptop version I received yet another error. A quick Google search suggested a staged update, that is, update to a firmware that is not quite as new as the latest, and from there go to the latest firmware.

I downloaded the oldest one available, version However, the esxcli help mentioned that installing unsigned VIBs would result in a warning being displayed in vSphere Client. If it gets annoying I can always install it and ignore the warning if any. I hope this helps someone. The official documentation is lacking so I thought I should share my experience. Thanks for the instructions! The zip 8. I installed this vib on a host running ESXi 5. I successfully upgraded my i to the latest firmware After reading your blog and using I wish the osm 3d documentation was a little bit more detailed so we could avoid these problems.

Your post helped a lot. I have been spending the last few days trying to downgrade my firmware without any success until I read your step-by-step instructions. This helped a lot. Thanks for taking the time to write this up. The LSI documentation really is lacking. I mean you can not even get the vibs to install without using the —no-sig-check but they fail to mention that to start with.

Thanks a lot. Your post helpful. Hi, Has anyone been able to successfully execute these commands in ESXi 6. For me on executing. Your email address will not be published. Subscribe to this comment feed via RSS. Name required :. Email required :. This site uses Akismet to reduce spam. Learn how your comment data is processed. Vigilance Theme by The Theme Foundry.

how to update firmware on LSI SAS RAID controller??

Home About.Forums New posts Search forums. New posts New posts New profile posts Latest activity. Members Current visitors New profile posts Search profile posts. Log in Register.

Search titles only. Search Advanced search…. New posts. Search forums. Log in. Install the app. Contact us. Close Menu.

Извлечение журналов RAID-контроллера с помощью Мегакли

JavaScript is disabled. For a better experience, please enable JavaScript in your browser before proceeding. You are using an out of date browser. It may not display this or other websites correctly. You should upgrade or use an alternative browser. Thread starter LibertySyclone Start date Oct 22, LibertySyclone [H]ard Gawd.

Joined Apr 9, Messages 1, I am dumbfounded by this stupid thing I can build the array and when I get into windows installer or recover from WHS and install the card drivers my "virtual" drive doesnt show up with my 2 Savvios in R0, but with my sata connector my 2 74GB raptors show up and will install windows. So this makes me think that it needs a firmware update? How do I do it?? I cant figure it out for the life of me and I am about to give someone a great deal on Savvio drives and a RAID controller Shaggy3zx [H]ard Gawd.

Joined Mar 17, Messages 1, According to the readme with the firmware you would update via MegaCLI. Drudenhaus 2[H]4U. Joined Sep 27, Messages 3, Gotcha I think So basically put it in a system that already has windows on it, install Mega CLI, update firmware, hope that it worksLSI is now owned by Avago Technologies. The models and cards remain the same, however the names may change down the road.

If you have a newer model than what is mentioned above, please use caution before you run any commands as the syntax and options have changed. I strongly suggest upgrading all RAID cards to the latest firmware versions and I also suggest making sure the OS driver is also updated to the latest version. As of March the latest firmware can be found below. Once you have unzipped the firmware, navigate to the directory where the rom is located and run the command below to begin the firmware update process.

You may need to reboot the server so be careful about updating firmware on a production server unless you are aware of the possible downtime involved with a reboot. To set a raid to use writethrough caching, install storcli and run this command:.

In general you will want to use writethrough caching with all SSD raids as you will get better performance compared to WriteBack. To update the firmware on an LSI card using Storcli you first need to download the latest firmware.

If you are using an LSI i card you can find the latest firmware here. Once you have downloaded the file you need to upload it to the server, unzip the file, then run the command below to update the card using the. To display all LSI RAID card details such as arrays, drives and the basic configuration of the card run the command below to query logical device info. If you want to get a list of all the physical drives that are hooked up to the LSI card, you can use the pdlist option to view all the disks.

If you want to enable Forced Write-Back mode on an LSI card you can run the command below which will immediately apply the new settings. I do not suggest using Forced Write Back mode unless you have to.

Using Write Back caching with SSDs is almost always going to result in slower performance, and if you don't have a BBU and you force write back caching you can lose data if the server hangs up or power is lost, so be careful with this setting. If you want to use Write Back caching but do not have a BBU then you have to use the command above to force write back caching.

I have no idea why you would but I'm including this option anyway. If you are using SSDs and want the best IO performance and want to make sure your data gets sent to disk asap, then you should be using Write Through caching, which is basically no cache at all. If you still live in the early 's and use spinning HDDs and want better performance then you should enable Read Ahead caching.MegaCLI can also be used as a troubleshooting tool.

You will need to unzip the file after download and choose the proper install package based on the operating system OS. More information about install procedures, bug fixes, and supported raid controllers are in the 8. This file is available once you have performed the initial unzip.

Detailed install procedures can be found in the read me file associated with each OS type. Refer to Cisco Technical Tips Conventions for more information on document conventions. This command displays the firmware log which includes environmental data, controller properties, memory information, events, and information about the Battery Backup Unit BBU such as physical properties, monitored information, capacity, and design information.

The output also provides event messages specific to the BBU. Displays information about all physical disk drives and other devices connected to the selected adapter s ; includes drive type, size, serial number, and firmware version. For SAS expanders: includes number of drives connected to expander. If the customer cannot install the MegaCLI utility or it is not available for some other reason, you can get to the Preboot CLI and run the same commands as shown above.

megacli firmware update

Contents Introduction.An update can be performed during operation and therefore the server does not need to be restarted. First you have to find out which enclosure ID you have and which ID the hard drive has. You can do this with the following command:. The next parameter specifies the path to the firmware file and the last one the controller number. If you have activated the onboard LSI controller and you also have an external controller, then the onboard LSI controller will have the ID 0 and the external controller will have the ID 1.

Flashing the hard drive may come the operating system to freeze. Under no circumstances should you cancel the operation. The update runs in the background and may take up to 5 minutes or longer. Please just wait patiently. After the update the operating system will operate normally. Views View View source History.

Personal tools Create account Log in. Thomas-Krenn Wiki.

Updating LSI MegaRAID firmware in VMware ESXi 5

Jump to: navigationsearch. Note: Please make sure you have a backup of your data. It is possible with LSI and Adaptec to flash multiple hard drives simultaneously. We do not recommend this method as some updates were aborted during the update process. When the update of the hard disk has been completed, you should see the following: You should wait about 15 seconds before continuing with the next hard drive update.

Note: Flashing the hard drive may come the operating system to freeze. Related articles. Adaptec arcconf CLI Commands.By using our site, you acknowledge that you have read and understand our Cookie PolicyPrivacy Policyand our Terms of Service. Server Fault is a question and answer site for system and network administrators. It only takes a minute to sign up. Recently we've found out there's a firmware update for our hard disks.

The server is a production server at a remote data center, so we can't afford shutting it down and booting off specific media to flash the firmware the old-and-reliable way. Also, the official PDF packaged with firmware states:.

RAID systems are extremely sensitive to disruptions to individual drives. It is not uncommon for low level disk drive diagnostics to cause RAID management software to fault a drive that is slowed down by testing or firmware download. For this reason, we highly recommend that you use disk management tools provided by your RAID controller manufacturer if they are available. LSI controllers are managed with the MegaCli utility.

Unfortunately, its documentation is extremely terse. Here's all it says about flashing firmware:. Flashes the firmware with the file specified at the command line. The firmware files used to flash a physical device can be of any format. The CLI utility assumes that you provide a valid firmware image, and it flashes the same. The physical device needs to do error checking. Searching the web hadn't revealed much too. This link is the only example of practical application we've found.

The procedure described at the link seems pretty trivial, but we have one big question left unanswered: is it sane to flash the firmware this way to disks holding the active RAID array? Especially when the OS is booted off the partition that's a part of this array?The megacli utility is also available in standard repos for many Linux distributions. I wanted to verify that the RAID controller would start an automatic rebuild.

I popped out one of the drives and the very loud alarm started screaming. I waited a little bit and put the drive back in. The alarm continued and the array did not start rebuilding. It turns out that the controller has some self-defense against someone mistakenly re-inserting a bad drive so it won't start an automatic rebuild on a drive that was just disconnected and reconnected. Drives that were previously in an array are marked as "Foreign" if they are reinserted.

Introduction to LSI's MegaCLI Utility

Replacing a drive with a true spare drive off the shelf triggers an auto-rebuild just fine unless the adapter's auto-rebuild property has been altered. Note that this does not permanently disable the alarm, it just silences the current alarm. If there is another RAID event such as when you replace the failed drive and a rebuild begins! I have only one adapter in each of my servers, so I can use "-aALL" to indicate all adapters.

If you have more than one adapter you might need to specify it by number such as "-a0". Some commands do not work against multiple adapters and require the specific adapter identifier. To manipulate a particular physical device, MegaCli wants it to be addressed by Enclosure and Slot. Removing a drive and putting it right back onto the same RAID controller will cause the drive to marked as "Foreign". A drive in the "Foreign" state is not usable in an array.

Show the first few lines of output for each drive to help locate the one that is in a "Foreign" state:. Manually inspect the output for the drive where "Firmware state" is not "Online". Drives that are already removed will not show up in this list. The following comments are owned by whomever posted them. This site is not responsible for what they say. RSS Feed for this blog.


Comments

Leave a Reply